Electric Steam Generator
Industrial Electric Steam Generator
- Capacity: 30~1000 kg/h
- Pressure: 0.4/0.7 Mpa
- Steam Temperature: 151/171℃
- Thermal Efficiency: >98%
- Fuel: Electricity
Introduction of Industrial Electric Steam Generator
Electricity is clean energy sources, electric energy has been used more and more widely in recent years. Not only electric heating steam boilers, but now, according to the needs of market development, electric heating steam generators have been developed.
The electric heating steam generator is mainly composed of automatic control system, water supply system, heating system, safety protection system, furnace boiler, etc., which can provide steam for the steam box and steam iron, etc. Therefore, it is widely used in food factories, clothing factories and restaurants. What is more, it has the advantages of energy saving and environmental protection.
Industrial Steam Generator Features
- Equipped with a touch screen control system to ensure the safety of boiler use, and also facilitate maintenance.
- Saturated steam can be generated in 3-5 minutes. Compared with traditional steam generators, it has higher thermal efficiency and is more energy saving.
- The use of electrical energy cause no pollution, no noise, meet environmental protection requirements.
- Equipped with safety accessories such as safety valve, globe valve and pressure controller to ensure the reliable operation of the boiler.
- The steam generator has anti-freezing function, avoiding the problem of freezing and cracking of pipelines and water pumps in cold winter.
- Very easy to operate, connect the water and electricity, and then press the control key to enter the running state automatically.
- Equipped with extremely low water level protection device to avoid dry burning and accidents.
- Compact structure, small footprint, convenient for transportation and installation.
Technical Specification
Model | Unit | LDR0.03 | LDR0.05 | LDRO.1 | LDR0.2 | LDR0.3 | LDR0.5 | LDR0.7 | LDR1.0 | |
Rated Capacity | KG/H | 30 | 50 | 100 | 200 | 300 | 500 | 700 | 1000 | |
Rated Input Power | KW | 24 | 36 | 72 | 144 | 216 | 360 | 504 | 720 | |
Working Pressure | MPA | 0.4 | 0.4/0.7 | |||||||
Steam Temperature | ℃ | 151 | 151/171 | |||||||
Thermal Efficiency | % | >98 | ||||||||
Fuel | Electricity | |||||||||
Power Supply | V | 380 | ||||||||
Frequency | HZ | 50/60 | ||||||||
Power Consumption | KW | 24 | 36 | 72 | 144 | 216 | 360 | 504 | 720 | |
Heating Element Power | KW | 24 | 18 | 24 | 24 | 24 | 45 | 72 | 72 | |
Heating Element Quantity | Pieces | 1 | 2 | 3 | 6 | 9 | 8 | 7 | 10 | |
Connection Diameter | Steam Outlet | DN | 15 | 20 | 25 | 25 | 32 | 40 | 40 | 50 |
Water Inlet | DN | 20 | 20 | 20 | 20 | 25 | 25 | 32 | 32 | |
Drain Discharge | DN | 20 | 20 | 20 | 25 | 25 | 40 | 40 | 50 | |
Safty Valve | DN | 20 | 20 | 20 | 20 | 20 | 25 | 25 | 25 | |
Water Capacity | KG | 25 | 25 | 25 | 25 | 25 | 25 | 29.5 | 29.5 | |
Gross Weight | T | 0.18 | 0.22 | 0.28 | 0.31 | 0.45 | 1.1 | 1.55 | 1.87 | |
Dimension | Length | MM | 300 | 450 | 500 | 700 | 800 | 900 | 1200 | 1400 |
Width | MM | 450 | 600 | 700 | 800 | 1000 | 1200 | 1500 | 1500 | |
Height | MM | 800 | 900 | 1000 | 1000 | 1350 | 1500 | 1650 | 2000 |